NE230
16 www.baumer.com
Line 37 activation of presets P1, P2
0 immediately active
1 after reset
Line 38 counting range P1,P2 and SC
0 positive only
1 positive and negative
Line 39 function key assignment
0 w/o function
1 XP
2 P1
3 P2
4 SC
5
Σ
6 Á
7 SF
Line 40 code
0000 code not active
:
9999
Line 41 batch counter function
0 totalizer
1 counting upon achieving P2
Line 42 batch counter multiplier (Line 41=1)
1 default
0 min.
999 max.
Line 43 offset
0 no offset
:
999999 max. offset value
Line 44 mains failure display
0 no mains failure display
1 mains failure display (blinking)
Line 51 Baud rate
0 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud
Line 52 parity
0 even parity
1 odd parity
2 no parity
Line 53 stop bits
0 1 stop bit
1 2 stop bits
Line 54 counter identification
00 default
00 min.
99 max.
Line 55 output value assignment by interface
Line 31=5
0 display value
1 XP
2 P1
3 P2
4 SC
5
Σ
6 Á
7 SF
Line 56 RS422: control connections TxD+ , TxD-
0 In sending direction during sending, in receiving direction during reception
1 always in sending direction