9. Programming plan
Line 11-17 Status line 1-7
0 * Enable parameter alteration
1 Clear resp. parameter lock
2 Skip parameter
Line 24 Decimal point F, P1, P2
0 * No decimal point
1 0000.0
2 000.00
3 00.000
Line 26 Measuring unit
0 * No measuring unit
1 1/h
2 1/min
3 1/s
Line 27 Standard display lower line
0 No lower display line
1 P1 – preset (limit)
2 * P2 – Preset (limit)
3 bF – Evaluation tacho F
4 b - batch counter
5 SF – scaling factor batch counter
Line 28 Update time (display repetition)
0 0,5s
1 * 1 s
2 2 s
3 3 s
4 5 s
5 10 s
6 20 s
7 30 s
8 60 s
Line 29 Timeout signal input B (terminal 8)
0 * 1 s
1 2 s
2 3 s
3 5 s
4 10 s
5 20 s
6 30 s
7 60 s
8 Timeout OFF
9 Timeout OFF, save recent value displayed
in
case of power failure
Line 30 Unit time tachometer
0 * 1/min
1 1/s
2 1/h
Line 31 Frequency track B tacho
0 * 40 kHz
1 25 Hz
Line 32 Frequency track A batch counter
0 * 10 kHz
1 25 Hz
2 3 Hz
Line 33 Input logic signal inputs A,B
0 * PNP trigger threshold 6 V
1 NPN trigger threshold 6 V
2 PNP trigger threshold 3 V
3 NPN trigger threshold 3 V
Line 34 Function control input 1 (terminal 9)
0 * Hold for tacho and batch counter
1 Programming lock
2 Keylock
3 Print
Line 35 Response time control input 1
0 * 30 ms
1 100 µs
Line 36 Function control input 2 (terminal 10)
0 Hold for tacho and batch counter
1 * Programming lock
2 Keylock
3 Print
Line 37 Function control input 3 (terminal 11)
0 * Batch counter – static reset
1 Batch counter – edge-triggered reset
2 Programming lock
3 Keylock
4 Print
Line 40 Output logic digital outputs
0 * Both outputs normally closed
1 P1 normally open, P2 normally closed
2 P1 normally closed, P2 normally open
3 Both outputs normally open
Line 47 Assignemnt limit P1
0 * Max. limit
1 Min. limit
Line 48 Assignment limit P2
0 * Max. limit
1 Min. limit
Line 49 Output response MIN.limit
0 * With starting lock (triggered only when
dropping below)
1 no starting lock
Line 50 Code
0000 * Code not active
:
9999
Line 51 Baudrate
0 * 4800 Baud
1 2400 Baud
2 1200 Baud
3 600 Baud
Line 52 Parity
0 * Even Parity
1 Odd Parity
2 No Parity
Line 53 Stop bits
0 * 1 Stop bit
1 2 Stop bits
Line 54 Identifier
00 * Default
00 Min.
99 Max.