PCD41
12 www.baumer.com
7. List of the control characters used
Control character Hex Decimal
<STX> 02 02
<ETX> 03 03
<LF> 0A 10
<CR> 0D 13
<DC1> 11 17
<CAN> 18 24
<DEL> 7F 127
8. Operating plan
Line Factory setting Short description
01
0 F - Tachometer display F
02 0 HIGH – Maximum-value memory (max. point)
03 0 bFdn – Display adjustment low value
04 4 0 9 5 bFuP – Display adjustment high value
05 1 0 0 0 P1 - Limit value P1
06 2 0 0 0 P2 - Limit value P2
- - - - - - Separating line
11 S t a t 0 F - Status for tachometer display F
12 S t a t 2 HIGH - Status for maximum-value memory (max. point)
13 S t a t 2 bFdn - Status for display adjustment low value
14 S t a t 2 bFuP - Status for display adjustment high value
15 S t a t 0 P1 - Status for limit value P1
16 S t a t 0 P2 - Status for limit value P2
- - - - - - Separating line
23 2 3 0 Input logic for control inputs
24 2 4 0 Decimal point
26 2 6 0 Offset
28 2 8 0 Update time (repeated display)
31 3 1 0 Function of control input 1 (Connection 11)
32 3 2 1 Function of control input 2 (Connection 12)
33 3 3 0 Allotment digital output 1
34 3 4 0 Allotment digital output 2
35 3 5 0 Output logic relay outputs
39 3 9 0 Hold delay period
40 4 0 C o d Code setting
0
51 5 1 0 Baud rate
52 5 2 0 Parity
53 5 3 0 Stop bits
54 5 4 0 Address
55 5 5 0 Allotment output value via interface (Line 31=5)
56 5 6 0 RS422: Control of connections TxD+, TxD-
- - - - - - Separating line