5.2 How to reset the factory settings using the teach button
Within 5 minutes after power up, the button may be used to reset the sensor back to the factory settings.
After finishing a teach procedure, the 5 minutes starts again. After the 5 minutes, the sensor does not
respond to the button.
1. Push the button. The red LED will turn on, if the sensor can be taught.
2. Hold down the button further 5 sec. The LED will start to blink. DO NOT RELEASE the button now. Wait
another 10 sec until the LED is ON without blinking. Factory settings have been restored to the sensor.
3. Release the button.
5.3 How to teach a new range using the external teach input
Teaching the sensor via the external teach input is equivalent to the teaching procedure via the button. There
is no 5 min. time limit. The sensor may be taught at any time.
Input circuit:
t1
Red LED
t12
Until button has been
released (t13)
27k
10kΩ
teach-in
low: 0 .. 2V
high: 12 .. 28V
3V3
Red LED
t1
t2
t3
t4
☺
0 V
12-28 V
t7 t8
t9
t6